See also discussion of adaptations made to units in this preamble under the heading "Costs of Adaptation" in the section entitled "Discussion of Comments on Related Fair Housing Issues"....
Search Results "Head Height"
Commonly Searched Documents
-
Bias Toward Wheelchair Users
-
11B-803.1 General
Section 903.5 requires dressing room bench seats to be installed so that they are at the same height as a typical wheelchair seat, 17 inches (430 mm) to 19 inches (485 mm)....
-
11B-303.5 Warning curbs
(102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning curbs at least 6 inches (152 mm) in height...
-
Handrail Extensions
Handrail Extensions ADAAG addresses handrail height, diameter, and extensions provided to the end of the gangway....
-
4(2)
(2) In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2....
-
Counters and Bars [5.2]
Types of Counters Maximum Height Minimum Length Knee Clearance (forward approach) Dining/Bars (service) 34 in 60 in required Dining/Bars...
-
Wall-Mounted Objects
Overhangs that are above cane sweep height may protrude 4 inches without being hazardous....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Power Chair
depict the reaching abilities of power chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Manual Wheelchair
depict the reaching abilities of manual chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Scooter
depict the reaching abilities of scooter users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach direction for a given (a) height...
-
Car Position Indicators [§407.4.8]
Specifications include: ½” min. character height Illumination of each floor level passed or stopped at Automatic verbal announcement of stop or non-verbal audible...
-
Transfer Surface (M301.2 and M302.2)
The technical criteria in M301.2 and M302.2 address the height and size of the transfer surface, and the transfer sides....
-
11B-303.5 Warning curbs
(102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning curbs at least 6 inches (152 mm) in height...
-
11B-603.5 Accessories
ETA Editor's Note The CBC 11B-603.5 limitation on the height of accessories at toilet rooms is more stringent than 2010 ADAS....
-
11B-803.1 General
Section 903.5 requires dressing room bench seats to be installed so that they are at the same height as a typical wheelchair seat, 17 inches (430 mm) to 19 inches (485 mm)....
-
11B-803.1 General
Section 11B-903.5 requires dressing room bench seats to be installed so that they are at the same height as a typical wheelchair seat, 17 inches (430 mm) to 19 inches (485 mm)....
-
11B-603.5 Accessories
ETA Editor's Note The CBC 11B-603.5 limitation on the height of accessories at toilet rooms is more stringent than 2010 ADA Standards....
- Disabled Sports USA
-
Avoid the extremes of surface reflectivity and contrast (slides 11 and 13)
And because building codes typically require stairs – treads and risers to be regular – you can’t have different heights and sizes....
-
Re: Service Counters
The entire depth of the lowered counter at 34" max height must be provided to allow for this unimpeded interaction instead of the higher employee counter condition which prevents equal access...
-
1023.9 Stairway identification signs
Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings two or more stories in height...
- PEMKO 7" Half Saddle/Offset Saddle Threshold No. 2727
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-V