806.2.6 Turning Space. Turning space complying with 304 shall be provided within the guest room....
Search Results "Clear Pier Space"
-
806.2.6 Turning Space
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
-
11B-603.2.1 Turning space
11B-603.2.1 Turning space. Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-703.2.7 Character spacing
11B-703.2.7 Character spacing. Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
1017.4.1 Size
The passing space shall be either: 1. A space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or 2....
-
1017.4.1 Size
The passing space shall be either: 1. A space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or 2....
-
8.5 Stacks
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....
-
8.5 STACKS
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....
-
11B-612.3 Turning space
11B-612.3 Turning space. A turning space complying with Section 11B-304 shall be provided within saunas and steam rooms....
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches....
-
Van Accessible Parking Spaces [§502.1 - 502.5]
Van Accessible Parking Spaces [§502.1 - 502.5] At least one space for every 6 or fraction of 6 accessible spaces must be van accessible....
-
11B-703.2.7 Character spacing
Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
T504 Passenger Access Routes
[See subsections ...]
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made...
-
206.7.2 Wheelchair Spaces
206.7.2 Wheelchair Spaces....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
10.3.1(16)
(16) Where provided in below grade stations, escalators shall have a minimum clear width of 32 inches....
-
11B-703.2.8 Line spacing
11B-703.2.8 Line spacing....
-
11B-206.4.5 Tenant spaces
[2010 ADAS] 206.4.5 Tenant Spaces. At least one accessible entrance to each tenancy in a facility shall comply with 404....
-
11B-206.4.5 Tenant spaces
[2010 ADAS] 206.4.5 Tenant Spaces. At least one accessible entrance to each tenancy in a facility shall comply with 404....
-
11B-206.4.5 Tenant spaces
[2010 ADA Standards] 206.4.5 Tenant Spaces. At least one accessible entrance to each tenancy in a facility shall comply with 404....
-
11B-224.1.2 Guest room doors and doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...