E1-c. Does the accessible route from the accessible entrance to all activity areas change levels using a ramp, lift or elevator? [ADA Standards §§ 4.1.3(1), 4.3.8] Yes ...
Search Results "Weather Shelter"
-
E1-c
-
d-i
d-i. Is the slope no greater than 1:12? [ADA Standards § 4.8.2] Yes No Note: For existing ramps, the slope may be 1:10 for a 6-inch rise and 1:8 for a 3-inch rise in...
-
F2
F2. If there is a built-in reception or other type of counter, does it have a section that is at least three feet long that is no higher than 36 inches above the floor or is there a...
-
C1-e
C1-e. Where an accessible route crosses a curb, is a curb ramp provided? [ADA Standards § 4.3.8] Yes No
-
g-v
g-v. If the answers to questions g-ii thru g-iv are No, can the door be propped open? Yes No If an activity area is not on an accessible route and cannot be made...
-
E1-d
E1-d. Where the slope of the accessible route is greater than 1:20, does this area meet the following requirements for an accessible ramp? Yes No
-
M10
M10. Are the drain and hot water pipes for the lavatory insulated or otherwise configured to protect against contact? [ADA Standards § 4.19.4] Yes No
-
D3
D3. Is the hardware (e.g., lever, pull, and panic bar) usable with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards § 4.13.9] Yes ...
-
E1-f
E1-f. If a wheelchair lift is provided, does it meet the following? Yes No
-
C1-f
C1-f. If the slope of part of the accessible route is more than 1:20, does it meet the following requirements for an accessible ramp? Yes No
-
d-vi
d-vi. Does the ramp have a level landing that is at least 60 inches long at the top and bottom of each ramp section or where the ramp changes direction? [ADA Standards §...
-
d-vii
d-vii. If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Standards § 4.8.7] Yes No
-
d-ii
d-ii. Are handrails installed on both sides of each ramp segment? [ADA Standards § 4.8.5] Yes No
-
M15
M15. Are all built-in dispensers, receptacles, or equipment mounted so the front does not extend more than 4 inches from the wall if the bottom edge is between 27 inches and 80...
-
H14
H14. Are all built-in dispensers, receptacles, or equipment mounted so the front does not extend more than 4 inches from the wall if the bottom edge is between 27 inches and 80...
-
H24
H24. Unless the wide stall is located at the end of a row of toilet stalls, does the door to this wider stall open out? [ADA Standards § 4.17.3] Yes No
-
C. Sidewalks and Walkways
C. Sidewalks and Walkways
-
e-vi
e-vi. Are signs mounted on both sides of the elevator hoist way door opening (for each elevator and at each floor) that designate the floor with 2-inch minimum-height raised letters...
-
J5
J5. Are the controls on or near the front of the unit and do they operate with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards §...
-
M18
M18. Is the flush valve located on the side adjacent to the lavatory? [ADA Standards § 4.16.5] Yes No
-
g-ii
g-ii. Is the door hardware (e.g., lever, pull, push, panic bar) usable with one hand, without tight grasping, pinching, or twisting of the wrist, to allow people who may not be able...
-
f-iii
f-iii. Is the ramp width, measured between the handrails, at least 36 inches? [ADA Standards § 4.8.3] Yes No
-
f-i
f-i. Is the running slope no greater than 1:12? [ADA Standards § 4.8.2] Yes No Note: For existing ramps, the slope may be 1:10 for a 6-inch rise and 1:8 for a 3-inch...
-
f-ii
f-ii. Are handrails installed on both sides of each ramp segment? [ADA Standards § 4.8.5] Yes No