106.5.33 Ground Level Play Component
-
Transfer Steps
Transfer Steps Transfer steps are level surfaces in a composite structure that can be used for transferring from different levels to access play components....
-
19. Are new play components added to an existing play area required to comply with the Standards even if there is not an accessible route from parking or the street to the play area?
Are new play components added to an existing play area required to comply with the Standards even if there is not an accessible route from parking or the street to the play area?...
-
18. Where an existing ground level play component is replaced, should the new component comply with the technical provisions of Section 1008.4 even if there is not an accessible route to it?
Where an existing ground level play component is replaced, should the new component comply with the technical provisions of Section 1008.4 even if there is not an accessible route to it?...
-
Existing play areas. (Section-by-Section Analysis)
50 percent of the elevated play components are accessible....
-
Transfer Supports
Transfer Supports A means of support is required when transferring into the entry or seat of a play component....
- PlayLSI Chimes Reach Panel Play Component
-
11B-240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
11B-240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
Turning Space: ADA Standard Section 1008.4.1
At least one turning space complying with 304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
Play Areas: ADA Standard Section 240
Section 240 covers scoping requirements in the current ADA Standards for play areas.
-
Play Areas: ADA Standard Section 206.2.17
Section 206.2.17 covers scoping requirements in the most current ADA Standards for accessible routes to play areas.
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3....
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3....
-
3. Are ramps, transfer systems, and stairs permitted to be counted as play components?
Are ramps, transfer systems, and stairs permitted to be counted as play components? No....
- Kompan, Inc. M591 - Waterfall Play Structure
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.