Self-closing panel covers the receptacle opening, removable 3 gal. (11.4 L) stainless steel waste receptacle. Recessed Waste Receptacle shall hold 3.1gal. (11.6 liters) of dry/solids...
Search Results "ECTCR: Existing Conditions That Can Remain"
- American Specialties Recessed Waste Receptacle 04733
- American Specialties Semi-Recessed Waste Receptacle 0458
- American Specialties Roval™ Collection Semi-Recessed Waste Receptacle 20458
- Bobrick ConturaSeries Recessed Waste Receptacle with LinerMate B-43644
- Bradley 12 Gallon Waste Receptacle
-
11B-206.2.3.2 Distance to Elevators
In existing buildings that exceed 10,000 square feet (929 m2) on any floor and in which elevators are required by Section 11B-206.2.3, whenever a newly constructed means of vertical access...
-
11B-206.2.3.2 Distance to Elevators
In existing buildings that exceed 10,000 square feet (929 m2) on any floor and in which elevators are required by Section 11B-206.2.3, whenever a newly constructed means of vertical access...
-
§ 35.150(b)(5) Exemption for small facilities
For measures taken to comply with the program accessibility requirements of this section, existing facilities shall comply with the applicable requirements for alterations in § 35.151 of...
-
Alterations
Under section 202.3 of the 2010 Standards entities can alter as many elements within a room or space as they like without triggering a requirement to make the entire room or space accessible...
-
F202.2.5 Drinking Fountain
Where a drinking fountain is not provided in an addition but is provided in the existing building or facility to serve the addition, at least one drinking fountain in the existing building...
- Magnuson Group SOTARE Waste Receptacles
-
C. Whether the City Can Assert an Undue Burden Defense With Respect to Existing Facilities Covered by Section 504 of the Rehabilitation Act
Whether the City Can Assert an Undue Burden Defense With Respect to Existing Facilities Covered by Section 504 of the Rehabilitation Act The parties disagree as to whether there is an...
- Magnuson Group SLOPE Waste Receptacles
-
11B-215.1 General
Exception: In existing facilities, visible alarms for fire alarm systems shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system...
-
11B-215.1 General
Exception: In existing facilities, visible alarms for fire alarm systems shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system...
- Magnuson Group VALUTA Waste Receptacles
- Magnuson Group STILO Waste Receptacles
-
11B-221.2.1.6 Specialty seating areas
Exception: In existing buildings and facilities, if it is not readily achievable for wheelchair spaces to be placed in each specialty seating area, those services or amenities shall be provided...
-
11B-221.2.1.6 Specialty seating areas
Exception: In existing buildings and facilities, if it is not readily achievable for wheelchair spaces to be placed in each specialty seating area, those services or amenities shall be provided...
-
F202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction....
-
4.1.5 ACCESSIBLE BUILDINGS: ADDITIONS
Each addition to an existing building shall comply with 4.1.1 to 4.1.4 of 4.1, Minimum Requirements, except as follows:...
-
Trash and Recycling Receptacles [1011.2 and 1011.3]
At trash and recycling containers, a minimum of 36 by 48 inches of clear ground space positioned for a forward approach to the receptacle opening, or a minimum of 30 by 60 inches...
-
Areas of sport activity. (Section-by-Section Analysis)
For purposes of the program accessibility requirement, as with play areas and swimming pools, where an existing facility provides multiple areas of sport activity that serve the same purpose...
-
Fishing piers and platforms. (Section-by-Section Analysis)
237 of the 2004 ADAAG require at least twenty-five percent (25%) of railings at fishing piers and platforms to be no higher than 34 inches high, so that a person seated in a wheelchair can...