5.4.5 Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and...
Search Results "Dialysis Chair"
Commonly Searched Documents
- 
    
  
  5.4.5 Transfer Support Position Recommendation for M301 and M302
  
 - 
    
  
  5.4.2 Transfer Support Length for M301 and M302
  
5.4.2 Transfer Support Length for M301 and M302 Description: Transfer support length applies to the gripping surface of the support, that portion of the support used to grasp or...
 - 
    
  
  5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surface cross section should comply with the...
 - 
    
  
  5.3 Transfer Sides
  
5.3 Transfer Sides.
 - 
    
  
  5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer support should be a minimum length of 15 inches positioned so that...
 - 
    
  
  5.3 Transfer Sides Recommendations
  
5.3 Transfer Sides Recommendations
 - 
    
  
  5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer gripping surface should be located within the minimum and maximum...
 - 
    
  
  5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The bottom of the transfer support shall have no...
 - 
    
  
  Emergency Travel Safety Tips for Overnight Stays
  
Edition 1 – October 2017 By June Isaacson Kailes This document was made possible with support from: Grant to North Carolina Emergency Management from The North...
 - 
    
  
  M305.2.1 Location
  
Transfer supports shall be located within reach of the transfer surface and shall not obstruct transfer onto or off of the surface when in position.
 - UpScale by Medical Accessibility - Adjustable Height Exam Table with Built-in Scale
 - 
    
  
  M305.2.2 Length (Section-by-Section Analysis)
  
In the MDE NPRM there was no requirement for length of the transfer support; however, the MDE NPRM preamble noted that the Access Board was considering requiring the transfer...
 - 
    
  
  5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
  
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302 Description: A clearance around the gripping surface is necessary to ensure sufficient space for...
 - 
    
  
  5.7 Lift Compatibility
  
5.7 Lift Compatibility.
 - 
    
  
  5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. There should be a 1½ inches minimum clearance around the...
 - 
    
  
  5.7 Lift Compatibility Recommendations
  
5.7 Lift Compatibility Recommendations
 - 
    
  
  5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
  
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer support should be located a maximum distance...
 - 
    
  
  M305.2.5 Surface Hazards
  
Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges.
 - 
    
  
  M305.2 Transfer Supports
  
Transfer supports shall comply with M305.2.
 - 
    
  
  M305.2 Transfer Supports (Section-by-Section Analysis)
  
This is an introductory section. As discussed above in Section IV.E.1. (Significant Changes – Transfer Supports), the Access Board strengthened the transfer support requirements and...
 - 
    
  
  M305.2.5 Surface Hazards (Section-by-Section Analysis)
  
The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports. No public comments were submitted on this issue, but the MDE...
 - 
    
  
  5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2
  
5.4.6 Transfer Support Gripping Surface Cross Section and Clearances for M301, M302, and M305.2 Description: This provision prescribes a cross-sectional profile of the transfer...
 - 
    
  
  5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
  
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302 Description: This minimum distance ensures that the transfer support is within reach of the...
 - 
    
  
  5.4 Transfer Supports
  
5.4 Transfer Supports.