Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1....
Search Results "Destination-Oriented Elevator"
-
11B-411.1 General
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
11B-411.1.2 Car designations
Elevator cars shall be designated with a single alphabetic character....
-
11B-411.2 Elevator landing requirements
Elevator landings shall comply with Section 11B-411.2....
-
11B-411.2.1 Hall call consoles
Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309.
-
11B-411.2.1.1 Location
Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or...
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker.
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3.
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4.
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5.
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-411.2.1.7 Elevator car assignment
When the accessibility function button is pressed, elevator car assignment shall comply with Section 11B-411.2.1.7....
-
11B-411.2.2 Elevator car identification at elevator landings
Elevator car identification shall comply with Section 11B-411.2.2....
-
11B-411.2.3 Signs on jambs of elevator hoistway entrances
Signs on jambs of elevator hoistway entrances shall comply with Section 11B-411.2.3....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3.
-
11B-411.3.1 Type
Elevator door type shall comply with Section 11B-407.3.1....
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5.
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
11B-411.4 Elevator car requirements
Elevator cars shall comply with Section 11B-411.4....
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-411.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-407.4.2....
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.