Search Results "Changes in Level"
Commonly Searched Documents
- PEMKO 5" Saddle Threshold No. 154
- PEMKO 8" Heavy Duty Threshold No. 1718
- PEMKO 3" Saddle Threshold No. 168
- PEMKO 4" Saddle Threshold No. 227
- PEMKO 3" Saddle Threshold No. 253
- PEMKO 5" Saddle Threshold No. 171
- PEMKO 4" Saddle Threshold No. 254
-
Leveling: ADA Standard Section 409.4.4
Section 409.4.4 covers the ADA Standards for the self-leveling feature in private residence elevators.
- Universal Changing Places
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. EXCEPTION: Where the surface is other...
-
1018.5 Obstacles
Obstacles on beach access routes and resting intervals shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point. EXCEPTION: Where the surface is other...
-
304.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surface Exception....
-
304.2 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
-
11B-304.2 Floor or Ground Surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
-
304.2 Floor or Ground Surfaces
Changes in level are not permitted. [ECTCR UFAS 4.2.4.3] EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
-
11B-304.2 Floor or Ground Surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
Carpet [4.5.3]
Studies show that the level of roll resistance of carpet, even low-pile carpet that is properly secured, is considerably higher than the roll resistance of firmer surfaces such as concrete...
-
4(2)
(2) In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2....
-
11B-813.2 Features
Adult changing facilities shall provide features in compliance with Section 11B-813.2....
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
-
Leveling: ADA Standard Section 408.4.4
Section 408.4.4 covers the ADA Standards for the self-leveling feature in limited-use/limited-application elevators.
-
11B-503.4 Floor and ground surfaces
Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-504.4 Tread surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....