, light switches and dispenser controls) shall comply with 4.27. 4.27.3 Exception: These requirements do not apply where the use of special equipment dictates otherwise or where electrical...
Search Results "Electrical Receptacle"
-
205 Operable Parts
-
205.1 General
Electrical or communication receptacles serving a dedicated use shall not be required to comply with 309. 3....
-
217.5 Shelves for Portable TTYs
a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone at the bank shall be provided with a shelf and an electrical...
-
Guest Rooms
Beds. Bed heights for accessible rooms should be between 17-23 inches above the floor Do not have border frame which prevents the wheelchair from being directly...
-
§ 35.151(b)(4)(i)(B)
(B) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of or access...
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes....
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes....
-
205.1 General
Electrical or communication receptacles serving a dedicated use shall not be required to comply with 309. 3....
-
217.5 Shelves for Portable TTYs
a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone at the bank shall be provided with a shelf and an electrical...
-
§ 35.151(b)(4)(i)(B)
(B) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of or access...
-
H12
For at least one of each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned...
-
What types of electrical or communication receptacles are exempt because they serve a “dedicated use”?
Electrical receptacles serving a dedicated use include those installed for appliances, including refrigerators, ranges, and dishwashers, and wall clocks....
-
Sec.36.403(c)(2)
(2) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of or access...
-
F205.1 General
Electrical or communication receptacles serving a dedicated use shall not be required to comply with 309. 3. ...
-
§100.205(c)
(c) All covered multifamily dwellings for first occupancy after March 13, 1991 with a building entrance on an accessible route shall be designed and constructed in such a manner that—
-
§100.205(c)(3)
(3) All premises within covered multifamily dwelling units contain the following features of adaptable design:
-
§100.205(c)(3)(ii)
(ii) Light switches, electrical outlets, thermostats, and other environmental controls in accessible locations;...
-
§100.205(d)
(d) The application of paragraph (c) of this section may be illustrated by the following examples: Example (1): A developer plans to construct a 100 unit condominium apartment...
-
F217.5 Shelves for Portable TTYs
a bank of telephones in the interior of a building consists of three or more public pay telephones, at least one public pay telephone at the bank shall be provided with a shelf and an electrical...
-
205 and 309 Operable Parts
The 1991 Standards, at section 4.27.3, contain an exception, “ * * * where the use of special equipment dictates otherwise or where electrical and communications systems receptacles are...
-
Reach Ranges
Changes in the side-reach range for new construction and alterations in the 2010 Standards will affect a variety of building elements such as light switches, electrical outlets, thermostats...
-
M13
For each type of dispenser, receptacle, or equipment, is there clear floor space at least 30 inches wide x 48 inches long adjacent to the control or dispenser (positioned either parallel...
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over...
-
Reach Ranges and Operable Parts
REACH RANGES AND OPERABLE PARTS Forward and side reach 11B-308.2/3 Over...