Section 403.3 covers the current ADA Standards for the slope of walking surfaces that are part of an accessible route.
Search Results "Shower Slope"
Commonly Searched Documents
-
Slope: ADA Standard Section 403.3
-
Slope: ADA Standard Section 405.2
Section 405.2 covers the current ADA Standards for slope requirements on ramps.
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
Cross Slope: ADA Standard Section 405.3
Section 405.3 covers the current ADA Standards for cross slope requirements on ramps.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
Shower Enclosures: ADA Standard Section 608.8
Section 608.8 covers the current ADA Standards for enclosures for shower compartments.
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.5.2
Section 608.5.2 covers the current ADA Standards for controls in standard roll-in type shower compartments.
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.3.2
Section 608.3.2 covers the current ADA Standards for grab bars in standard roll-in type shower compartments.
-
Slope: ADA Standard Section 810.5.1
Rail platforms shall not exceed a slope of 1:48 in all directions....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.3.3
Section 608.3.3 covers the current ADA Standards for grab bars in alternate roll-in type shower compartments.
-
Counter Slope: ADA Standard Section 406.2
Section 406.2 covers the current ADA Standards for counter slope of adjoining gutters and road surfaces immediately adjacent to curb ramps.
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
Transfer Type Shower Compartments: ADA Standard Section 608.2.1
Section 608.2.1 covers the current ADA Standards for the size and clearances of transfer type shower compartments.
-
Transfer Type Shower Compartments: ADA Standard Section 608.3.1
Section 608.3.1 covers the current ADA Standards for grab bars in transfer type shower compartments.
-
Size and Clearances for Shower Compartments: ADA Standard Section 608.2
Section 608.2 covers the current ADA Standards for the size and clearances of shower compartments.
-
Shower Compartments: ADA Standard Section 608
Section 608 covers the current ADA Standards for shower compartments.
-
Standard Roll-In Type Shower Compartments: ADA Standard Section 608.2.2
Section 608.2.2 covers the current ADA Standards for the size of standard roll-in type shower compartments.
-
Slope: ADA Standard Section 1002.4.2
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.2.3
Section 608.2.3 covers the current ADA Standards for the size and clearances of alternate roll-in type shower compartments.
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
Slope: ADA Standard Section 810.2.4
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
Thresholds: ADA Standard Section 608.7