No, latch clearance 12” minimum is required for forward approaches on the push-side of doors equipped with both a closer and a latch....
Search Results "Push Side"
Commonly Searched Documents
-
Is additional latch side clearance required on the push side of doors with a forward approach when either a latch or closer (but not both) is provided?
-
Side Reach: ADA Standard Section 308.3
Section 308.3 covers the current ADA Standards for side reach.
-
Side Wall: ADA Standard Section 604.5.1
Section 604.5.1 covers the current ADA Standards for side wall grab bars that are used for water closets.
-
Push Plates, Buttons, and Bars
Push-activated controls not requiring more than 5 lbf are acceptable. Buttons that are raised or flush are easier to use than those that are recessed....
-
Side Entry: ADA Standard Section 1002.4.4.2
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
- Figure 404.2.4.1(k) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side with Closer – Drawing from the U.S. Access Board
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
Door and Gate Surfaces [§404.2.10]
Door and Gate Surfaces [§404.2.10] The bottom surface of doors and gates on the push side must be smooth to a height of at least 10”....
-
Operable Parts: ADA Standard Section 704.2.2
Telephones shall have push-button controls where such service is available....
-
11B-704.2.2 Operable parts
Telephones shall have push-button controls where such service is available....
- Figure 404.2.4.1(f) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(j) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side – Drawing from the U.S. Access Board
-
11B-703.4.2 Location
where sign installation locations identified in Section 11B-703.4.2 are obstructed or otherwise unavailable for sign installation, signs with tactile characters shall be permitted on the push...
- Figure 404.2.4.1(g) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
- Figure 404.2.4.1(b) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(c) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
-
4.31.6 Controls
Telephones shall have push button controls where service for such equipment is available....
-
Sides of Curb Ramps: ADA Standard Section 406.3
Section 406.3 covers the current ADA Standards for curb ramp flares.
-
11B-406.2.2 Sides of curb ramps
Where provided, curb ramp flares shall not be steeper than 1:10.
-
4.31.3* MOUNTING HEIGHT
The highest operable part of the telephone shall be within the reach ranges specified in 4.2.5 or 4.2.6.
-
4.31.6 CONTROLS
Telephones shall have pushbutton controls where service for such equipment is available.
-
Controls and Switches
Flip switches and similar controls are acceptable, though push plate types can provide easier access....
-
Clearances for Side Approaches
Clearances for Side Approaches Clearance for side approaches are based on the swing of doors, direction of approach (hinge or latch), and the provision of closers (in some cases latches...
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....