Section 308.2.2 covers the current ADA Standards for obstructed high reach.
Search Results "Obstructed Reach"
Commonly Searched Documents
-
Obstructed High Reach: ADA Standard Section 308.2.2
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
308.2.2 Obstructed High Reach
308.2.2 Obstructed High Reach....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
Obstructed High Reach
The maximum high reach is reduced to 46” when the reach over an obstruction is deeper than 10” (to a maximum of 24”)....
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
- Figure 308.2.2 Obstructed High Forward Reach – Drawing from the U.S. Access Board
-
3.3.15.3 Side (lateral) reach – over an obstruction depth of 610 mm
3.3.15.3 Side (lateral) reach – over an obstruction depth of 610 mm The vast majority of WhMD users in our study that displayed some reach capability could not reach at or beyond a 610...
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an obstructed forward reach is provided, the maximum allowable forward reach to an...
-
Obstructed Reach Depth
Obstructed Reach Depth...
-
407.8.3.2 Obstructed Forward Reach
The maximum allowable forward reach to an operable part shall be 25 inches (635 mm)....
-
407.12.3.2 Obstructed Forward Reach
The maximum allowable forward reach to an operable part shall be 25 inches (635 mm). Figure 407.12.3.2...
-
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach
Table 407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach Reach Depth Operable Part Height Less than 20 inches (510 mm) 48 inches...
-
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis)
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis) This section proposes that, where the operable part is located more than 10 inches, but not more than 24 inches, behind...
-
Obstructed High Reach
The maximum reach of 48” is reduced to 44” when the depth of reach over an obstruction exceeds 20.” Knee and toe space must extend the full depth of reach....
-
Side Reach: ADA Standard Section 308.3
Section 308.3 covers the current ADA Standards for side reach.
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
407.8.2.2 Obstructed Side Reach
Where the operable part is located more than 10 inches (255 mm), but not more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be...
-
407.12.2.2 Obstructed Side Reach
Where the operable part is located more than 10 inches (255 mm), but not more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be...