Section 206.6 requires each passenger elevator to comply with the requirements for standard elevators or destination-oriented elevators....
Search Results "LU/LA: Limited Use/Limited Application Elevator"
-
Passenger Elevators
-
206.6 Elevators
Elevators provided for passengers shall comply with 407. Where multiple elevators are provided, each elevator shall comply with 407. EXCEPTIONS: 1....
-
Priority 2: Access to Goods & Services
Word Fillable Form (2.5MB) Word Non-Fillable Form (2.4MB) PDF Non-Fillable Form (1.4MB)
-
Elevators and Platform Lifts
Elevators and Platform Lifts In addition to regular elevators, limited use/limited application elevators (smaller, slower elevators used for low-traffic, low-rise facilities) or platform...
-
Elevators and Platform Lifts
Elevators and Platform Lifts In addition to regular elevators, limited use/limited application elevators or platform lifts that comply with ADAAG may be used instead of gangways as part...
-
206.6 Elevators
206.6 Elevators. Elevators provided for passengers shall comply with 407....
-
408 Limited-Use/Limited-Application Elevators
Section 408 provides requirements for limited-use/limited-application (LULA) elevators which correspond to section 407.4 in the proposed rule....
-
LULA Elevator Dimensions
The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
-
F206.6 Elevators
Elevators provided for passengers shall comply with 407. Where multiple elevators are provided, each elevator shall comply with 407. EXCEPTIONS: 1....
-
408 Limited-Use/Limited-Application Elevators
-
408.1 General
Limited-use/limited-application elevators shall comply with 408 and with ASME A17.1 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
408.2 Elevator Landings
Landings serving limited-use/limited-application elevators shall comply with 408.2....
-
408.2.1 Call Buttons
Elevator call buttons and keypads shall comply with 407.2.1....
-
408.2.2 Hall Signals
Hall signals shall comply with 407.2.2.
-
408.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3.1....
-
408.3 Elevator Doors
Elevator hoistway doors shall comply with 408.3....
-
408.3.1 Sliding Doors
Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1.
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2.
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1).
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated.
-
408.4 Elevator Cars
Elevator cars shall comply with 408.4....
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
408.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
408.4.3 Platform to Hoistway Clearance
The platform to hoistway clearance shall comply with 407.4.3.