R409.3 Continuity. Handrails shall be continuous within the full length of each ramp run or stair flight....
Search Results "Handrail Continuity"
Commonly Searched Documents
-
R409.3 Continuity
-
Continuity: ADA Standard Section 505.3
Section 505.3 covers the current ADA Standards for the continuity of handrails.
-
Can handrail extensions wrap or turn?
Handrail extensions must be in the same direction as the stair flight, but continuous handrails can wrap at the inside turn of switchback or dogleg stairways....
-
Handrail Extensions: ADA Standard Section 505.10
Section 505.10 covers the current ADA Standards for handrail extensions.
-
§ 38.29(c)
(c) For vehicles in excess of 22 feet in length, overhead handrail(s) shall be provided which shall be continuous except for a gap at the rear doorway....
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
Top and Bottom Extension at Ramps: ADA Standard Section 505.10.1
Section 505.10.1 covers the current ADA Standards for the top and bottom handrail extensions at ramps.
-
Bottom Extension at Stairs: ADA Standard Section 505.10.3
Section 505.10.3 covers the current ADA Standards for the handrail extensions at the bottom of the stairs.
-
Top Extension at Stairs: ADA Standard Section 505.10.2
Section 505.10.2 covers the current ADA Standards for the handrail extensions at the top of the stairs.
-
Handrail Height: ADA Standard Section 1008.2.5.3.2
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
Handrails [§405.8, §505]
Handrails [§405.8, §505] Handrails are required on both sides of ramps with a rise greater than 6”....
-
Stairway Handrails Requirements in the ADA Standards (§504)
Stairway Handrails Requirements in the ADA Standards (§504) Protruding Objects The ADA Standards address hazards posed by protruding objects, such as standpipe valves, along...
-
Fittings: ADA Standard Section 505.9
Section 505.9 covers the current ADA Standards for handrail fittings.
-
Gripping Surface: ADA Standard Section 505.6
Section 505.6 covers the current ADA Standards for the handrail gripping surface.
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
Handrails: ADA Standard Section 1009.6.2
The width between handrails shall be 20 inches (510 mm) minimum and 24 inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
Surfaces: ADA Standard Section 505.8
Section 505.8 covers the current ADA Standards for handrail gripping surfaces and also any adjacent surfaces to them.
-
Continuous Width (R302.3) (Section-by-Section Analysis)
Continuous Width (R302.3) (Section-by-Section Analysis) The continuous clear width of pedestrian access routes (exclusive of the width of the curb) must be 1.2 meters (4 feet) minimum...
-
Handrails: ADA Standard Section 1009.3.3
At least two handrails complying with 505 shall be provided on the sloped entry....
-
11B-1009.6.2 Handrails
The width between handrails shall be 20 inches (508 mm) minimum and 24 inches (610 mm) maximum....
-
Handrails: ADA Standard Section 504.6
Section 504.6 covers the current ADA Standards for handrails at stairways.
-
11B-505.10.3 Bottom extension at stairs
The horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of the sloping portion of the handrail as measured above the stair nosings....
-
Cross Section: ADA Standard Section 505.7
Section 505.7 covers the current ADA Standards for the cross section of handrail gripping surfaces.