The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
Search Results "Exterior Door"
Commonly Searched Documents
-
11B-809.8.2 Door opening force
-
Exterior Site Requirement: ADA Standard Section 217.4.4
Section 217.4.4 covers scoping requirements in the current ADA Standards for TTYs at exterior sites.
-
11B-404.2.9 Door and gate opening force
Exterior hinged doors: 5 pounds (22.2 N) maximum....
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
-
Exterior/ Fire Doors
Exterior/ Fire Doors A maximum opening force is not specified for exterior swing doors because the closing force required by building codes usually exceeds an "accessible" resistance....
-
Exterior Spaces: ADA Standard Section 806.2.2
Exterior spaces, including patios, terraces and balconies, that serve the guest room shall be accessible. [S.H. 9.2.2(6)(d)]...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
Door Delay: ADA Standard Section 407.3.5
Section 407.3.5 covers the current ADA Standards for elevator door delay.
-
1132A.2 Interior doors and secondary exterior doors
1132A.2 Interior doors and secondary exterior doors....
-
1132A.2 Interior doors and secondary exterior doors
Except as allowed by Section 1109A.2, interior doors intended for user passage and secondary exterior doors shall comply with this section....
-
1132A.2 Interior doors and secondary exterior doors
Except as allowed by Section 1109A.2, interior doors intended for user passage and secondary exterior doors shall comply with this section....
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
-
1132A.3 Width and height of interior doors and secondary exterior doors
1132A.3 Width and height of interior doors and secondary exterior doors. Doors shall comply with the following:...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....
-
Elevator Door Requirements: ADA Standard Section 407.3
Section 407.3 covers the current ADA Standards for elevator door requirements.
-
Opening Force
Fire doors are required to have the minimum opening force permitted by the appropriate administrative authority. No maximum opening force was proposed for exterior hinged doors....
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. ...
-
Door Closers and Gate Closers: ADA Standard Section 404.2.8.1
Section 404.2.8.1 covers the current ADA Standards for the closing speed of door closers and gate closers.
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following:...
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
16. Opening Building Doors
For paratransit services, a passenger's request for the driver to open an exterior entry door to a building to provide boarding and/or alighting assistance to a passenger with a disability...
-
Door and Signal Timing: ADA Standard Section 407.3.4
Section 407.3.4 covers the current ADA Standards for door and signal timing of elevator reopening devices.
-
Entrance
One commenter requested clarification on whether "entrance" refers to an entry door to a dwelling unit, or an entry door to the building. Response....