Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
Search Results "Exterior Area for Assisted Rescue"
Commonly Searched Documents
-
1009.7.2 Separation
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
1007.8 Exterior area for assisted rescue
The exterior area for assisted rescue must be open to the outside air and meet the requirements of Section 1007.6.1....
-
1003.2.13.7 Exterior area for assisted rescue
The exterior area for assisted rescue must be open to the outside air and meet the requirements of Section 1003.2.13.5.1....
-
1009.7.1 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3....
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.9 at doors to areas of refuge and exterior areas for assisted rescue shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5...
-
Exterior Area for Assisted Rescue [IBC§1007.8 (2003), §1003.2.13.7 (2000)]
[See subsections ...]
-
1007.7 Exterior area for assisted rescue
1007.7 Exterior area for assisted rescue. Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1007.7.4 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1007.8.1 Openness
The exterior area for assisted rescue shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1007.7.5 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
1003.2.13.7.1 Openness
The exterior area of refuge shall be at least 50 percent open, and the open area above the guards shall be so distributed as to minimize the accumulation of smoke or toxic gases....
-
G. Areas of Rescue Assistance
Areas of Rescue Assistance - In hotels that do not have a supervised fire sprinkler system serving every room, are there two 30"x48" wheelchair waiting areas (a.k.a. an "area of rescue assistance...
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
5) Areas of rescue assistance or places of refuge
5) Areas of rescue assistance or places of refuge ADAAG: Areas of rescue assistance (safe areas in which to await help in an emergency) are generally required on each floor, other than the...
-
1007.8.3 Identification
Exterior areas for assisted rescue shall have identification as required for area of refuge that complies with Section 1007.6.5....