Section 602.7 covers the current ADA Standards for drinking fountains for standing persons.
Search Results "Drinking Fountain"
Commonly Searched Documents
-
Drinking Fountains for Standing Persons: ADA Standard Section 602.7
-
Drinking Fountains: ADA Standard Section 602
Section 602 covers the current ADA Standards for drinking fountains.
-
Drinking Fountains: ADA Standard Section 211
Section 211 covers scoping requirements in the current ADA Standards for drinking fountains.
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
-
Water Flow: ADA Standard Section 602.6
Section 602.6 covers the current ADA Standards for the drinking fountain water flow.
-
Minimum Number: ADA Standard Section 211.2
Section 211.2 covers scoping requirements in the current ADA Standards for the minimum number of drinking fountains that are required.
-
More Than Minimum Number: ADA Standard Section 211.3
Section 211.3 covers scoping requirements in the current ADA Standards for when there are more than the minimum number of drinking fountains provided.
-
11B-211.3 More than minimum number
Where more than the minimum number of drinking fountains specified in Section 11B-211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with Sections...
-
11B-211.2 Minimum number
No fewer than two drinking fountains shall be provided....
-
General: ADA Standard Section 211.1
Section 211.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for drinking fountains.
-
General: ADA Standard Section 602.1
Section 602.1 of the ADA Standards covers information in the current ADA Standards for drinking fountains.
-
Spout Height: ADA Standard Section 602.4
Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
-
Spout Location: ADA Standard Section 602.5
Section 602.5 covers the current ADA Standards for the spout location of drinking fountains.
-
Drinking Fountains
Error/Omission: All drinking fountains are mounted with the spout at 36" A.F.F....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
211 Drinking Fountains
fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use wheelchairs in accordance with 4.15 and one accessible to those who have difficulty...
-
11B-602.1 General
Drinking fountains shall comply with Sections 11B-307 and 11B-602....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
H. Drinking Fountains
Drinking Fountains - Are at least 50% of the drinking fountains on each floor mounted so the spout is no higher than 36"?...
-
11B-602.6 Water flow
The purpose of requiring the drinking fountain spout to produce a flow of water 4 inches (100 mm) high minimum is so that a cup can be inserted under the flow of water to provide a drink...
-
Drinking Fountains for Standing Persons
Specifications for drinking fountains for standing persons address the height of the spout outlet (602.7)....
-
211 and 602 Drinking Fountains
211 and 602 Drinking Fountains Sections 4.1.3(10) and 4.15 of the 1991 Standards and sections 211 and 602 of the 2010 Standards require drinking fountains to be provided for persons who...
-
602.7 Drinking Fountains for Standing Persons
602.7 Drinking Fountains for Standing Persons....
-
R212.2 Drinking Fountains
R212.2 Drinking Fountains. Drinking fountains shall comply with sections 602.1 through 602.6 of Appendix D to 36 CFR part 1191....