TM 2013-11 Benches Effective Date: June 1, 2013 2012 TAS Reference: 903 Based on information received from the U.S....
Search Results "Bench"
-
Technical Memorandum TM 2013-11 Benches
-
Outdoor Constructed Feature
A constructed element provided at an outdoor recreation site such as a picnic table; fire ring; pedestal grill; tent pad; bench; trash, recycling, or other essential container; fireplace...
-
4.4 Benches
-
4.4.2 Height
The front edge of the seat of a bench shall be at least 17 inches (430 mm) and no more than 19 inches (485 mm) above the floor or ground. ...
-
4.4.3 Backrest and Armrest
When more than one bench is provided in the same area, at least 50 percent of the benches shall have a backrest running the full length of the bench....
-
4.4.4 Clear Floor or Ground Space
The long dimension of the clear space shall be roughly perpendicular to the length of the bench....
-
4.4.5 Slope
The slope of the clear floor or ground space for benches shall not exceed 1:48 (2 percent) in any direction. Exception....
-
4.4.6 Surface
The surface of the clear floor or ground space for benches shall be firm and stable. The type of surface should be appropriate to the setting and level of development....
-
G. Women's Spa and Fitness Center Locker Room
(5) Defendants will provide a wall-mounted or fixed bench at least 42 inches long and 20-24 inches deep in the Women's Fitness Center Locker room, the Women's Spa accessible dressing...
-
H. Men's Spa and Fitness Center Locker Room
(3) Defendants will provide a wall-mounted or fixed bench at least 42 inches long and 20-24 inches deep in the Men's Fitness Center Locker room, and the Men's Spa accessible dressing...
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
Attachment H: Modifications to Altered Facilities
Attachment H: Modifications to Altered Facilities
-
903 Benches
-
903.1 General
Benches shall comply with 903....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
903.4 Back Support
The bench shall provide for back support or shall be affixed to a wall....
-
903.6 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device,...
-
Priority 2: Access to Goods & Services
Word Fillable Form (2.5MB) Word Non-Fillable Form (2.4MB) PDF Non-Fillable Form (1.4MB)
-
R212.6 Benches
R212.6 Benches. At least 50 percent, but no less than one, of benches at each location shall provide clear space complying with R404 adjacent to the bench....
-
Benches
Benches Accessible benches are required in dressing, fitting, and locker rooms, and where seating is provided in saunas and steam rooms....
-
Current Accessibility Guidelines That Apply to the Forest Service
Docks Fishing piers and platforms New or reconstructed: Picnic areas Fire rings Picnic tables Grills Woodstoves Benches...
-
4.3 Locker Room Barriers and Solutions
Remove the locking mechanism and attach a handle that is easy to use Benches in the dressing area are too narrow Ask staff to put a chair in dressing area Replace the...
-
903 Benches
The Board has clarified that the clear floor or ground space is to be "parallel to the short axis of the bench." Comment....
-
Seat Height
The proposed rule specified that the bench seat be 17 to 19 inches above the floor or ground (903.4)....