2012 Florida Accessibility Code for Building Construction Pocket Guide
703.3 Braille. Braille shall be contracted (Grade 2) and shall comply with 703.3 and 703.4.
703.3.1 Dimensions and Capitalization. Braille dots shall have a domed or rounded shape and shall comply with Table 703.3.1. The indication of an uppercase letter or letters shall only be used before the first word of sentences, proper nouns and names, individual letters of the alphabet, initials, and acronyms.
Table 703.3.1 Braille Dimensions
MEASUREMENT RANGE |
MINIMUM IN INCHES MAXIMUM IN INCHES |
---|---|
Dot base diameter |
0.059 (1.5 mm) to 0.063 (1.6 mm) |
Distance between two dots in the same cell1 |
0.090 (2.3 mm) to 0.100 (2.5 mm) |
Distance between corresponding dots in adjacent cells1 |
0.241 (6.1 mm) to 0.300 (7.6 mm) |
Dot height |
0.025 (0.6 mm) to 0.037 (0.9 mm) |
Distance between corresponding dots from one cell directly below1 |
0.395 (10 mm) to 0.400 (10.2 mm) |
Figure 703.3.1 Braille Measurement
703.3.2 Position. Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text. Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements.
EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters or symbols.
Figure 703.3.2 Position of Braille
User Comments/Questions