A constructed feature such as a sign that extends into the trail tread more than 4 inches (100 mm) between 27 inches (685 mm) and 80 inches (2030 mm) above the trail tread. ...
Search Results "Trail"
-
Protruding Object
-
Trail
For purposes of the FSTAG and FSORAG, a trail is a pedestrian route developed primarily for outdoor recreational hiking purposes. ...
-
Trail Grade
The ascent or descent of a trail segment expressed as a percentage of its length. When expressed as a ratio of rise to length to the term used is running slope....
-
Trail Segment
The portion of a trail being planned, evaluated, or constructed....
-
Trail Terminus
For the purpose of the FSTAG the trail terminus is the beginning or ending point of a trail or trail segment, where a trail assessment or trail work begins or ends....
-
7.4.1 Surface
The trail tread surface, including resting intervals and passing spaces, shall be both firm and stable....
-
7.4.2 Clear Tread Width
The clear tread width of the trail shall be at least 36 inches (915 mm)....
-
7.4.4 Resting Intervals
Where the trail grade exceeds 1:20 (5 percent), resting intervals shall be provided as specified in Table 7.4.3.1....
-
7.4.4.3 Slope
The slope of a resting interval shall not exceed 1:20 (5 percent) in any direction. Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper...
-
7.4.5 Passing Spaces
Trails with a clear tread width less than 60 inches (1525 mm) shall provide passing spaces complying with 7.4.5 at intervals of 1000 feet (300 m) maximum. ...
-
7.4.5.1 Size
The passing space shall be either: A space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or The intersection of two trails providing a T-shaped space complying...
-
7.4.5.2 Slope
The cross slope of a passing space shall not exceed 1:20 (5 percent) in any direction.
-
7.4.5.3 Non-complying Segment Ends
Where a segment of the trail does not comply with 7.4, a passing space shall be located at the end of each adjacent trail segment that does comply with 7.4....
-
7.4.8 Protruding Objects
Constructed features, including signs, shall not extend into the trail tread more than 4 inches (100 mm) between 27 inches (685 mm) and 80 inches (2030 mm) above the surface of the trail...
-
7.4.10.2 Outdoor Recreation Access Routes (ORARs)
access route complying with FSORAG section 2.0 shall connect the following places at trailheads: Accessible parking spaces or other arrival point; Starting point of the trail...
-
7.4.12 Gates and Barriers
Where gates or barriers are constructed to control access to trails, gates and barriers shall comply with 7.4.12....
-
7.4.12.1 Clear Width
Gate openings and openings in barriers for hiker passage shall provide a clear width of 36 inches (915 mm), complying with ODAAG, section 1017.3 Clear Tread Width.
-
7.4.12.2 Gate Hardware
Gate hardware shall comply with operable controls requirements in ABAAS section 309.4 and 404.2.7.
-
Summary of Costs and Benefits
We estimate the final rule would result in additional costs for viewing areas, trails, and beach access routes shown in Table 3....
-
Exceptions When Conditions Do Not Permit Full Compliance
permits exceptions based on the conditions to any provision in the technical requirements for tent pads and tent platforms, camp shelters, viewing areas, outdoor recreation access routes, trails...
-
Exemptions for Entire Trail or Beach Access Route
percent for over 20 feet; A trail obstacle 30 inches high or more runs across the full tread width of the trail; The trail surface is neither firm nor stable for a distance...
-
F201.4.1 Documentation and Notification When Exceptions Used for Trails or Beach Access Routes
This section requires federal agencies to document the basis for not fully complying with a specific provision in the technical requirements for trails on a portion of a trail based on Exception...
-
F247 Trails
-
F247.1 General
section requires the trail to comply with the technical requirements for trails in 1017....