Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
Search Results "Vertical Grab Bar"
-
609.2.2 Non-Circular Cross Section
-
1009.4.1 Clear Deck Space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall....
-
607.4.1 Bathtubs with Permanent Seats
For bathtubs with permanent seats, grab bars shall be provided in accordance with 607.4.1....
-
607.4.2 Bathtubs without Permanent Seats
For bathtubs without permanent seats, grab bars shall comply with 607.4.2....
-
609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
201.1.1 Vertical accessibility
201.1.1 Vertical accessibility....
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....
-
221.1.1 Florida Vertical Accessibility
221.1.1 Florida Vertical Accessibility....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
806.4 Hotel, Motel and Condominium Special Accessibility Features
percent of the guest rooms minus the Total Number of Required (accessible) Rooms required by Table 224.2 shall provide the following additional special accessibility features: (i) Grab...
-
221.2.3.2 Vertical Dispersion
221.2.3.2 Vertical Dispersion. Wheelchair spaces shall be dispersed vertically at varying distances from the screen, performance area, or playing field....
-
502.5 Vertical Clearance
502.5 Vertical Clearance. Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum....
-
307.4 Vertical Clearance
307.4 Vertical Clearance. Vertical clearance shall be 80 inches (2030 mm) high minimum....
-
503.5 Vertical Clearance
503.5 Vertical Clearance....
-
1008.2 Accessible Routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches high (2030 mm) minimum....
-
410.1 General
Inclined stairway chairlifts and inclined and vertical platform lifts are available for short-distance vertical transportation....
-
303.2 Vertical
303.2 Vertical. Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical. Figure 303.2 Vertical Change in Level...
-
226.1 General
226.1 General. Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall...
-
606.2 Clear Floor Space
A parallel approach complying with 305 shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided and to wet bars. 2....
-
607.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
608.6 Shower Spray Unit and Water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....