216.4.1 Exit Doors. Doors at exit passageways, exit discharge, and exit stairways shall be identified by tactile signs complying with 703.1, 703.2, and 703.5....
Search Results "Exit"
-
216.4.1 Exit Doors
-
207.1.1
207.1.1 Barriers at common or emergency entrances and exits of business establishments conducting business with the general public that are existing, under construction, or under contract...
-
202.3.3 Barriers at Common or Emergency Entrances and Exists
Barriers at common or emergency entrances and exits of business establishments conducting business with the general public that are existing, under construction, or under contract for construction...
-
207 Accessible Means of Egress
207 Accessible Means of Egress
-
216 Signs
216 Signs
-
703 Signs
703 Signs
-
703.4.1 Height above Finish Floor or Ground
703.4.1 Height above Finish Floor or Ground. Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the...
-
703.5.7 Stroke Thickness
703.5.7 Stroke Thickness. Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4.
-
703.5.8 Character Spacing
703.5.8 Character Spacing. Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters...
-
703.5.4 Character Proportions
703.5.4 Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 percent minimum and 110 percent maximum of the height of the...
-
703.5.3 Style
703.5.3 Style. Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
216.1 General
216.1 General. Signs shall be provided in accordance with 216 and shall comply with 703. EXCEPTIONS: 1. Building directories, menus, seat and row designations in assembly areas,...
-
703.5.6 Height from Finish Floor or Ground
703.5.6 Height from Finish Floor or Ground. Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating...
-
703.4.2 Location
703.4.2 Location. Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with...
-
703.1 General
703.1 General. Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
703.5.5 Character Height
703.5.5 Character Height. Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an...
-
703.5.1 Finish and Contrast
703.5.1 Finish and Contrast. Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark...
-
703.5.2 Case
703.5.2 Case. Characters shall be uppercase or lowercase or a combination of both.
-
216.2 Designations
216.2 Designations. Interior and exterior signs identifying permanent rooms and spaces shall comply with 703.1, 703.2, and 703.5. Where pictograms are provided as designations of...
-
703.5.9 Line Spacing
703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
203.9 Employee Work Areas
employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so that individuals with disabilities can approach, enter, and exit...
-
703.5 Visual Characters
703.5 Visual Characters. Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they...
-
238.2.1 Teeing Grounds
Where one teeing ground is provided for a hole, the teeing ground shall be designed and constructed so that a golf car can enter and exit the teeing ground....