602.7 Drinking Fountains for Standing Persons....
Search Results "Drinking Fountain Spout Height"
-
602.7 Drinking Fountains for Standing Persons
-
602.4 Spout Height
602.4 Spout Height. Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
602.5 Spout Location
602.5 Spout Location....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
602 Drinking Fountains
602 Drinking Fountains...
-
211 Drinking Fountains
211 Drinking Fountains...
-
211.2 Minimum Number
No fewer than two drinking fountains shall be provided. One drinking fountain shall comply with 602.1 through 602.6 and one drinking fountain shall comply with 602.7....
-
211.3 More Than Minimum Number
Where more than the minimum number of drinking fountains specified in 211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with 602.1 through 602.6...
-
211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with 211....
-
602.1 General
Drinking fountains shall comply with 307 and 602....
-
602.3 Operable Parts
602.3 Operable Parts. Operable parts shall comply with 309.
-
602.2 Clear Floor Space
EXCEPTION: A parallel approach complying with 305 shall be permitted at units for children’s use where the spout is 30 inches (760 mm) maximum above the finish floor or ground and is 3½...
-
102 Dimensions for Adults and Children
In addition, this document includes technical requirements based on children's dimensions and anthropometrics for drinking fountains, water closets, toilet compartments, lavatories and sinks...
-
903.5 Height
903.5 Height. The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground....
-
202.4.2 Accessible Features in the Event of Disproportionality
accessible entrance; (ii) an accessible route to the altered area; (iii) at least one accessible restroom for each sex or a single unisex restroom; (iv) accessible telephones; (v) accessible drinking...
-
202.2 Additions
202.2 Additions. Each addition to an existing building or facility shall comply with the requirements for new construction. Each addition that affects or could affect the usability...
-
1009.2.4 Seat Height
1009.2.4 Seat Height....
-
606.3 Height
606.3 Height. Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (865 mm) maximum above the finish floor or ground....
-
902.3 Height
902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
605.2 Height and Depth
605.2 Height and Depth. Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
1008.2.5.3.2 Handrail Height
1008.2.5.3.2 Handrail Height. The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
902.4.2 Height
902.4.2 Height. The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
604.9.3 Height
604.9.3 Height. The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
804.3.2 Height
804.3.2 Height. The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....