Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
Search Results "Compartment Door"
Commonly Searched Documents
-
604.8.2.2 Doors
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
213.3.1 Toilet Compartments
213.3.1 Toilet Compartments. Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1....
-
604.8 Toilet Compartments
604.8 Toilet Compartments. Wheelchair accessible toilet compartments shall meet the requirements of 604.8.1 and 604.8.3....
-
604.9.7 Toilet Compartments
604.9.7 Toilet Compartments. Toilet compartments shall comply with 604.8....
-
604.8.2 Ambulatory Accessible Compartments
604.8.2 Ambulatory Accessible Compartments. Ambulatory accessible compartments shall comply with 604.8.2....
-
604.8.1 Wheelchair Accessible Compartments
604.8.1 Wheelchair Accessible Compartments. Wheelchair accessible compartments shall comply with 604.8.1....
-
608 Shower Compartments
608 Shower Compartments...
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
608.2 Size and Clearances for Shower Compartments
608.2 Size and Clearances for Shower Compartments. Shower compartments shall have sizes and clearances complying with 608.2....
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
404.2.4.2 Doorways without Doors or Gates
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors....
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
604.9 Water Closets and Toilet Compartments for Children’s Use
604.9 Water Closets and Toilet Compartments for Children’s Use. Water closets and toilet compartments for children’s use shall comply with 604.9....
-
604.8.1.3 Approach
Compartments shall be arranged for left-hand or right-hand approach to the water closet....
-
407.3.5 Door Delay
407.3.5 Door Delay. Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
404.3.4 Doors in Series and Gates in Series
404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6....
-
604 Water Closets and Toilet Compartments
604 Water Closets and Toilet Compartments...
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
407.3 Elevator Door Requirements
407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3....
-
404.2.2 Double-Leaf Doors and Gates
404.2.2 Double-Leaf Doors and Gates. At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4....
-
404.3 Automatic and Power-Assisted Doors and Gates
404.3 Automatic and Power-Assisted Doors and Gates. Automatic doors and automatic gates shall comply with 404.3....
-
404.2.8.1 Door Closers and Gate Closers
404.2.8.1 Door Closers and Gate Closers....
-
409.3 Elevator Doors
409.3 Elevator Doors. Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....