Detectable warnings at track crossings shall be 36 inches (914 mm) in the direction of pedestrian travel and extend the full width of the circulation path....
Search Results "Track Crossing"
-
11B-705.1.2.7 Track crossings
-
11B-247.1.2.7 Track crossings
Where it is necessary to cross tracks to reach transit boarding platforms, detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.7 shall be provided....
-
11B-810.10 Track crossings
Where a circulation path serving boarding platforms crosses tracks, it shall comply with Section 11B-402....
-
MARKED CROSSING
[DSA-AC] A crosswalk or other identified path intended for pedestrian use in crossing a vehicular way....
-
CROSS SLOPE
[DSA-AC] The slope that is perpendicular to the direction of travel.
-
11B-609.2 Cross section
Grab bars shall have a cross section complying with Section 11B-609.2.1 or 11B-609.2.2....
-
11B-405.3 Cross slope
Cross slope of ramp runs shall not be steeper than 1:48. Advisory 11B-405.3 Cross slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
-
11B-705.1.1.3 Color and contrast
11B-705.1.1.3 Color and contrast. Detectable warning surfaces shall comply with Section 11B-705.1.1.3.1. The material used to comply with this section shall be an integral part of...
-
11B-609.2.1 Circular cross section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-206.2.19 Pedestrian street crossings
provided, a curb ramp, blended transition, or a combination of curb ramps and blended transitions complying with Section 11B-406 shall connect the walks or sidewalks at each pedestrian street crossing...
-
11B-505.7 Cross section
Handrail gripping surfaces shall have a cross section complying with Section 11B-505.7.1 or 11B-505.7.2....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-505.7.1 Circular cross section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
11B-406.6 Islands
Raised islands in crossings shall be cut through level with the street or have curb ramps at both sides....
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
11B-406.5.9 Clear space at diagonal curb ramps
Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1219 mm) minimum clear space within the markings....
-
11B-406.5.1 Location
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides. Exception: Diagonal curb ramps shall comply with Section 11B-406.5.9....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
11B-1003.2.1 Boat slips
The cross slope specified in Sections 11B-403.3 and 11B-405.3 for gangways, transition plates, and floating piers that are part of accessible routes shall be measured in the static position...
-
11B-810.5.1 Slope
Exception: Where platforms serve vehicles operating on existing track or track laid in existing roadway, the slope of the platform parallel to the track shall be permitted to be equal to...
-
11B-607.7 Bathtub enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub....
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....