Hand-operated metering faucets shall remain open for 10 seconds minimum....
Search Results "Slope Meter"
-
11B-606.4 Faucets
-
11B-810.5.1 Slope
Rail platforms shall not exceed a slope of 1:48 in all directions....
-
11B-405.3 Cross slope
Cross slope of ramp runs shall not be steeper than 1:48. Advisory 11B-405.3 Cross slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
-
RUNNING SLOPE
[DSA-AC] The slope that is parallel to the direction of travel. (As differentiated from the definition of “Cross Slope”.)...
-
11B-405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12. Exception: Reserved....
-
CROSS SLOPE
[DSA-AC] The slope that is perpendicular to the direction of travel....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-406.4.1 Slope
Blended transitions shall have a running slope not steeper than 1:20....
-
11B-1009.3.1 Sloped entries
Sloped entries shall comply with Division 4 except as modified in Sections 11B-1009.3.1 through 11B-1009.3.3....
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
11B-1009.3 Sloped entries
Sloped entries shall comply with Section 11B-1009.3. Advisory 11B-1009.3 Sloped entries. Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
11B-1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
11B-1009.2.3 Clear deck space
The clear deck space shall have a slope not steeper than 1:48....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
11B-504.4 Tread surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
11B-1009.3.3 Handrails
At least two handrails complying with Section 11B-505 shall be provided on the sloped entry....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-242.3 Wading pools
Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
11B-503.4 Floor and ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
11B-1007.2 Accessible routes
A slope not steeper than 1:4 for a 4 inch (102 mm) maximum rise shall be permitted. Ramp landing slopes specified by Section 11B-405.7.1 shall be permitted to be 1:20 maximum....