National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471 72-25: National Fire Alarm and Signaling Code, as amended* 407.4.4.5.1, 407.4.4.6, 901.6, 903.4.1,...
Search Results "NFPA: National Fire Protection Association"
-
NFPA
-
NFPA
[DSA-AC] The National Fire Protection Association....
-
CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To...
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADA Standards] 405.9 Edge Protection....
-
11B-1005.3 Edge protection
Where railings, guards, or handrails complying with Section 11B-1005.2 are provided, edge protection complying with Section 11B-1005.3.1 or 11B-1005.3.2 shall be provided....
-
BHMA
Builders Hardware Manufacturers’ Association 355 Lexington Avenue, 15th Floor New York, NY 10017 A 156.10-2022: Power Operated Pedestrian Doors 1010.3.2, 11B-404.2.9, 11B-404.3...
-
11B-405.9.2 Curb or barrier
ETA Editor's Note CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the extended floor or ground surface also permitted by 2010 ADA Standards...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface. The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face...
-
11B-702 Fire alarm systems
[See subsections ...]
-
11B-703.8.12 Protective covering
Where a protective layer is placed over VMS characters through which the VMS characters must be viewed, the protective covering shall have a non-glare finish....
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
[See subsections ...]
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
11B-243 Shooting facilities with firing positions
[See subsections ...]
-
11B-1010 Shooting facilities with firing positions
[See subsections ...]
-
ANSI
[DSA-AC] The American National Standards Institute....
-
11B-215 Fire alarm systems and carbon monoxide alarm systems
[2010 ADA Standards] 215 Fire Alarm Systems ETA Editor’s Note The CBC includes carbon monoxide alarm systems. Therefore, the CBC is more inclusive....
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3....
-
11B-243.1 General
Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with Section...
-
11B-809.5.1 Building fire alarm system
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
1009.12 Alarms/emergency warning systems/accessibility
Emergency warning systems provided as part of the fire-alarm system and two-way communication systems required by Chapter 10 shall be designed and installed in accordance with NFPA 72 as...
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform.
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
-
11B-809.5.1.2 Activation
All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion...