Emergency controls shall comply with Section 11B-407.4.6.4....
Search Results "Emergency Control"
-
11B-411.4.6.3 Emergency controls
-
11B-407.4.6.4 Emergency controls
Emergency controls shall comply with Section 11B-407.4.6.4....
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
11B-411.4.9 Emergency communication
Emergency communication shall comply with Section 11B-407.4.9....
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7....
-
11B-607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....
-
11B-407.4.9 Emergency communication
Emergency two-way communication systems shall comply with Section 11B-308....
-
11B-409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car....
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4....
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309.
-
11B-605.4 Flush controls
Flush controls shall be hand operated or automatic....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
11B-604.6 Flush controls
Flush controls shall be hand operated or automatic....
-
11B-407.4.6 Elevator car controls
Where provided, elevator car controls shall comply with Sections 11B-407.4.6 and 11B-309.4....
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
1009.12 Alarms/emergency warning systems/accessibility
Required emergency warning systems shall activate a means of warning the hearing impaired....
-
11B-407.4.7 Designations and indicators of car controls
Designations and indicators of car controls shall comply with Section 11B-407.4.7....
-
11B-411.2.1.4.2 Security or access controls
Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility....
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush....
-
11B-411.4.6 Elevator car controls
Where provided, elevator car controls shall comply with Sections 11B-411.4.6 and 11B-309.4....
-
11B-703.7.2.3 Volume control telephones
Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 11B-703.7.2.3....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...