Where towel bars are provided they shall be installed 40 inches (1016 mm) maximum above the finish floor to the top of the bar....
Search Results "Towel Bar"
-
11B-809.10.8.7 Mirrors and towel bars
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Where mirrors or towel bars are provided, no less than one of each shall comply with this section....
-
11B-604.8.1.5 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-606.1 General
If soap and towel dispensers are provided, they must be located within the reach ranges specified in Section 11B-308, except for those in toilet and bathing rooms which must comply with...
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
GRAB BAR
[DSA-AC] A bar for the purpose of being grasped by the hand for support. Advisory Definition of GRAB BAR....
-
11B-1009.5.7 Grab bars
At least one grab bar on each transfer step and the transfer platform or a continuous grab bar serving each transfer step and the transfer platform shall be provided....
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
11B-607.4 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped or U-shaped grab bar meeting the dimensional requirements of Section 11B-607.4.1 or 11B-607.4.2...
-
11B-809.10.2 Number of complying bathing rooms and fixtures
Lavatories, vanities, mirrors and towel bars complying with Section 11B-809.10.8. When two or more lavatories are provided, at least one shall comply with Section 11B-809.10.8....
-
11B-604.5 Grab bars
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
11B-609 Grab bars
[See subsections ...]
-
WET BAR
[DSA-AC] An area or space with a counter equipped with a sink and running water but without cooking facilities.
-
11B-603.5 Accessories
Where towel or sanitary napkin dispensers, waste receptacles, or other accessories are provided in toilet facilities, at least one of each type shall be located on an accessible route....
-
11B-212.2 Kitchens, kitchenettes, and wet bars
Kitchens, kitchenettes and wet bars shall comply with Section 11B-804. [2010 ADA Standards] 212.2 Kitchens and Kitchenettes. Kitchens and kitchenettes shall comply with 804....
-
11B-609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with Section 11B-609....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-604.8.2.3 Grab bars
Grab bars shall comply with Section 11B-609. A side-wall grab bar complying with Section 11B-604.5.1 shall be provided on both sides of the compartment....
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....
-
1607.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...