The angle of the water stream shall be measured horizontally relative to the front face of the unit....
Search Results "Stream Height"
-
11B-602.6 Water flow
-
11B-903.5 Height
The top of the bench seat surface shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the finish floor or ground.
-
11B-606.3 Height
ETA Editor's Note Top-mounted sinks installed in counters having the top surface 34 inches above the floor will exceed the maximum rim height allowed, regardless of how thin the flange...
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
11B-804.3.2 Height
Exception: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted....
-
11B-703.8.9 Height above floor
Heights of low resolution variable message sign characters shall comply with Table 11B-703.8.4, based on the size of the characters on the sign....
-
11B-411.4.11.1 Height
Floor destination characters shall be 1 inch (25 mm) high minimum complying with Section 11B-703.5.3.
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface.
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (343 mm) deep minimum...
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 11B-505.4 Height....
-
11B-703.8.4 Character height
The uppercase letter “I” shall be used to determine the allowable height of all low resolution VMS characters of a font....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground.
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface. Exception: Where a guard complying with Chapter 10,...
-
11B-504.2 Treads and risers
All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum....
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5....
-
11B-703.4.1 Height above finish floor or ground
[2010 ADA Standards] 703.4.1 Height Above Finish Floor or Ground....
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum.