[See subsections ...]
Search Results "Refueling Assistance"
-
11B-706 Assistive listening systems
-
ASSISTIVE LISTENING SYSTEM (ALS)
[DSA-AC] An amplification system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction...
-
1009.7.3 Openness
The exterior area for assisted rescue shall be open to the outside air....
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
11B-219.4 Location
If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot (15240 mm) viewing distance of the stage or playing area...
-
11B-703.7.2.4 Assistive listening systems
Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 11B-703.7.2.4....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
11B-219.5 Permanent and portable systems
Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating...
-
1009.7.1 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3....
-
11B-219 Assistive listening systems
[See subsections ...]
-
11B-404.3 Automatic and power-assisted doors and gates
Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19. Advisory 11B-404.3 Automatic and power-assisted doors and gates. ...
-
11B-706.5 Signal-to-noise ratio
The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum....
-
11B-404.3.1 Clear width
ETA Editor's Note CBC clear width requirement is more stringent at multi-leaf automatic and power-assisted doors than 2010 ADA Standards, since it must be provided by one door leaf....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.9 at doors to areas of refuge and exterior areas for assisted rescue shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5...
-
11B-706.2 Receiver jacks
Receivers required for use with an assistive listening system shall include a 1/8 inch (3.2 mm) standard mono jack....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6.
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route.
-
11B-706.6 Peak clipping level
Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
-
11B-219.2 Required systems
An assistive listening system shall be provided in assembly areas, including conference and meeting rooms. [2010 ADA Standards] 219.2 Required Systems....
-
11B-219.1 General
Assistive listening systems shall be provided in accordance with Section 11B-219 and shall comply with Section 11B-706....
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
11B-219.3 Receivers
Receivers complying with 706.2 shall be provided for assistive listening systems in each assembly area in accordance with Table 219.3....
-
11B-706.1 General
Assistive listening systems are generally categorized by their mode of transmission....