Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
Search Results "Lavatory Clear Floor Space"
-
11B-306.3.3 Minimum required depth
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-309.2 Clear floor space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
11B-704.2.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided. The clear floor or ground space shall not be obstructed by bases, enclosures, or seats....
-
CLEAR FLOOR SPACE
[DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
11B-804.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
11B-305 Clear floor or ground space
[See subsections ...]
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. Advisory 11B-407.2.1.3 Clear floor or ground space....
-
11B-1005.4 Clear floor or ground space
At each location where there are railings, guards, or handrails complying with Section 11B-1005.2.1, a clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-1002.5.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the amusement ride seats designed for transfer....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 11B-1004.1 Clear floor space....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-305.1 General
Clear floor or ground space shall comply with Section 11B-305....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
11B-602.2 Clear floor space
Units shall have a clear floor or ground space complying with Section 11B-305 positioned for a forward approach and centered on the unit....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....