Exit access stairways that connect levels in the same story are not permitted as part of an accessible means of egress....
Search Results "Exit"
-
1009.3.1 Exit access stairways
-
EXIT
That portion of a means of egress system between the exit access and the exit discharge or public way....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
1013.4 Raised character and braille exit signs
Where exit signs are provided at an area of refuge with direct access to a stairway, an exterior area for assisted rescue, an exit stairway or ramp, an exit passageway, a horizontal exit...
-
1028.5 Access to a public way
The exit discharge shall provide a direct and unobstructed access to a public way....
-
SECTION 1013 EXIT SIGNS
[See subsections ...]
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
11B-207 Accessible means of egress
Editor's Note From DSA's "Summary of 2022 California Building Code Changes for Accessibility in the Triennial Code Cycle": "Code amendment relocates Exceptions 1 and 2 (relating to exits...
-
1009.3.2 Stairway width
The clear width of 48 inches (1219 mm) between handrails is not required for stairways accessed from a refuge area in conjunction with a horizontal exit....
-
1009.3.3 Area of Refuge
Exceptions: Areas of refuge are not required at exit access stairways where two-way communication is provided at the elevator landing in accordance with Section 1009.8....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
1009.2.1 Elevators required
In buildings where a required accessible floor or occupied roof is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall...
-
1009.2 Continuity and components
Interior exit stairways complying with Sections 1009.3 and 1023, and Chapter 11A, Section 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
11B-206.4.1 Entrances
Editor's Note From DSA's "Summary of 2022 California Building Code Changes for Accessibility in the Triennial Code Cycle": "Code amendment relocates Exceptions 1 and 2 (relating to exits...
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
11B-703.5.6 Height from finish floor or ground
Floor-level exit signs complying with Chapter 10, Section 1013.7 shall not be required to comply with Section 11B-703.5.6....
-
1009.11 Instructions
The instructions shall include all of the following: Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with Sections 1009.4.1 and 1009.4.2.
-
1009.3 Stairways
[DSA·AC & HCD 1-AC] In addition, exit stairways shall comply with Chapter 11A, Sections 1115A and 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....