., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than 1/2 inch (12.7 mm) of change in height between floor surfaces....
Search Results "Drinking Fountain Spout Height"
-
11B-809.8 Doors
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
11B-705.1.1.1 Dome size
warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and 0.47 inch (11.9 mm) maximum, and a height...
-
11B-411.2.1.2.3 Accessibility function button
The International Symbol of Accessibility shall comply with Section 11B-703.7.2.1, and shall be 5/8 inch (15.9 mm) minimum in height. The indication shall be three raised dots....
-
11B-812.7.3 Lettering
The words “NO PARKING” shall be painted on the surface within each access aisle in letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent vehicular...
-
11B-225.2.3 Library book stacks
ETA Editor's Note The ADA Advisory identifies library shelving as self-service shelving, which does not have a height limitation....
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
11B-703.5.8 Character spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
11B-203.6 Single occupant structures
Single occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground...
-
11B-411.2.2.1 Visible identification
The characters on the fixture shall be upper case with a height of 4 inches (102 mm) minimum complying with Sections 11B-703.5.1, 11B-703.5.3, 11B-703.5.4, 11B-703.5.7 and 11B-703.5.8....
-
PUBLIC WAY
of land open to the outside air leading to a street, that has been deeded, dedicated or otherwise permanently appropriated to the public for public use and which has a clear width and height...
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-306.3.4 Clearance reduction
inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (152 mm) in height...
-
ALTERATION
resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height...
-
11B-502.8.2 Lettering
The additional sign shall clearly state in letters with a minimum height of 1 inch (25 mm) the following: "Unauthorized vehicles parked in designated accessible spaces not displaying...
-
11B-809.10.6.4 Reinforcement for grab bars
The grab bar reinforcement shall be 8 inches (203 mm) minimum in height....
-
3. Medical Diagnostic Equipment
has issued a notice of proposed rulemaking (NPRM) to remove the sunset provisions in the our existing accessibility standards for medical diagnostic equipment (MDE) related to the low-height...
-
11B-809.5.5.2 Identification
Such peepholes can be placed at a standard height and permit a view from several feet from the door. ◼...
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field....
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
-
11B-809.10.7.3 Reinforcement for grab bars
The grab bar reinforcement shall be 8 inches (203 mm) minimum in height. The backing shall 40 (sic) inches (1016 mm) minimum in length....
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor. ...
-
11B-303.5 Warning curbs
(102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning curbs at least 6 inches (152 mm) in height...