Where provided, bus shelters shall comply with Section 11B-810.3....
Search Results "Bus Shelter"
-
11B-218.4 Bus shelters
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
11B-810.2 Bus boarding and alighting areas
Bus boarding and alighting areas shall comply with Section 11B-810.2. Advisory 11B-810.2 Bus boarding and alighting areas....
-
11B-810.4 Bus signs
Bus route identification signs shall comply with Sections 11B-703.5.1 through 11B-703.5.4, and Sections 11B-703.5.7 and 11B-703.5.8....
-
11B-209.2.2 Bus loading zones
In bus loading zones restricted to use by designated or specified public transportation vehicles, each bus bay, bus stop, or other area designated for lift or ramp deployment shall comply...
-
11B-238.2.3 Weather shelters
Where provided, weather shelters shall be designed and constructed so that a golf car can enter and exit the weather shelter and shall comply with Section 11B-1006.4....
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
11B-218 Transportation facilities
[See subsections ...]
-
11B-218.1 General
Transportation facilities shall comply with Section 11B-218.
-
11B-209.2.3 On-street bus stops
On-street bus stops shall comply with Section 11B-810.2 to the maximum extent practicable....
-
11B-810.2.3 Connection
Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with Section 11B-402....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
11B-209 Passenger drop-off and loading zones and bus stops
209 Passenger Loading Zones and Bus Stops ETA Editor’s Note The CBC includes passenger drop-off. Therefore, the CBC is more inclusive....
-
11B-1006.4 Weather shelters
A clear floor or ground space 60 inches (1524 mm) minimum by 96 inches (2438 mm) minimum shall be provided within weather shelters....
-
11B-810.2.1 Surface
Bus stop boarding and alighting areas shall have a firm, stable surface....
-
11B-216.13 Variable message signs
Where provided in buildings that are designed as emergency shelters, variable message signs conveying emergency-related information shall comply with Section 11B-703.8....
-
11B-238.2 Golf courses
Golf courses shall comply with Section 11B-238.2.
-
11B-217.4.7 Transportation facilities
In transportation facilities, in addition to the requirements of Sections 11B-217.4.1 through 11B-217.4.4, where at least one public pay telephone serves a particular entrance to a bus or...
-
11B-218.5 Other transportation facilities
In other transportation facilities, public address systems shall comply with Section 11B-810.7 and clocks shall comply with Section 11B-810.8.
-
11B-705.1.1.3 Color and contrast
11B-705.1.1.3 Color and contrast. Detectable warning surfaces shall comply with Section 11B-705.1.1.3.1. The material used to comply with this section shall be an integral part of...
-
11B-238.1 General
Golf facilities shall comply with Section 11B-238.
-
11B-238 Golf facilities
[See subsections ...]