The water closet shall be positioned with a wall or partition to the rear and to one side....
Search Results "Water Closet Centerline"
-
604.2 Location
-
213.3.2 Water Closets
Where water closets are provided, at least one shall comply with 604....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
604 Water Closets and Toilet Compartments
[See subsections ...]
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
604.9.4 Grab Bars
Grab bars for water closets shall comply with 604.5....
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
604.9.2 Clearance
Clearance around a water closet shall comply with 604.3....
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat....
-
604.8.1.5 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear...
-
203.11 Water Slides
Water slides shall not be required to comply with these requirements or to be on an accessible route....
-
604.5 Grab Bars
Grab bars for water closets shall comply with 609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. EXCEPTIONS: 1....
-
609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with 609.
-
213.3 Plumbing Fixtures and Accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with 213.2 shall comply with 213.3.
-
502.1 General
Where parking spaces are marked with lines, width measurements of parking spaces and access aisles shall be made from the centerline of the markings....
-
102 Dimensions for Adults and Children
In addition, this document includes technical requirements based on children's dimensions and anthropometrics for drinking fountains, water closets, toilet compartments, lavatories and sinks...
-
609.4 Position of Grab Bars
shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water...
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1. Doors...