Hand-operated metering faucets shall remain open for 10 seconds minimum....
Search Results "Slope Meter"
-
606.4 Faucets
-
403.3 Slope
The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48....
-
810.5.1 Slope
Rail platforms shall not exceed a slope of 1:48 in all directions....
-
405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
405.3 Cross Slope
Cross slope of ramp runs shall not be steeper than 1:48. Advisory 405.3 Cross Slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
-
1009.3.1 Sloped Entries
Sloped entries shall comply with Chapter 4 except as modified in 1009.3.1 through 1009.3.3....
-
106.5.22 Cross Slope
The slope that is perpendicular to the direction of travel (see running slope)....
-
106.5.56 Running Slope
The slope that is parallel to the direction of travel (see cross slope)....
-
1009.3 Sloped Entries
Sloped entries shall comply with 1009.3. Advisory 1009.3 Sloped Entries. Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
406.2 Counter Slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20....
-
810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
1009.2.3 Clear Deck Space
The clear deck space shall have a slope not steeper than 1:48....
-
504.4 Tread Surface
EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface....
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
242.3 Wading Pools
Accessible means of entry shall comply with sloped entries complying with 1009.3....
-
1009.3.3 Handrails
At least two handrails complying with 505 shall be provided on the sloped entry....
-
503.4 Floor and Ground Surfaces
EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
802.1.1 Floor or Ground Surface
EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
1007.2 Accessible Routes
A slope not steeper than 1:4 for a 4 inch (100 mm) maximum rise shall be permitted. 4. Ramp landing slopes specified by 405.7.1 shall be permitted to be 1:20 maximum. 5....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
502.4 Floor or Ground Surfaces
EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 502.4 Floor or Ground Surfaces....
-
304.2 Floor or Ground Surfaces
EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surface Exception....