Where elevator call buttons or keypads are provided, they shall comply with 407.2.1 and 309.4. Call buttons shall be raised or flush....
Search Results "Hall Call Console"
-
407.2.1 Call Controls
-
409.2 Call Buttons
Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension and shall comply with 309....
-
407.2.1.2 Size
Call buttons shall be 3/4 inch (19 mm) minimum in the smallest dimension. EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....
-
407.2.1.6 Keypads
Where keypads are provided, keypads shall be in a standard telephone keypad arrangement and shall comply with 407.4.7.2.
-
407.2.2.2 Visible Signals
Signals shall be visible from the floor area adjacent to the hall call button. EXCEPTIONS: 1....
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
-
408.2.1 Call Buttons
Elevator call buttons and keypads shall comply with 407.2.1....
-
407.2.1.4 Location
The call button that designates the up direction shall be located above the call button that designates the down direction....
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
407.2.1.3 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at call controls. Advisory 407.2.1.3 Clear Floor or Ground Space....
-
407.2.2 Hall Signals
Hall signals, including in-car signals, shall comply with 407.2.2....
-
206.6.1 Existing Elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator...
-
408.2.2 Hall Signals
Hall signals shall comply with 407.2.2....
-
407.2.2.1 Visible and Audible Signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car's direction of travel....
-
407.2.2.3 Audible Signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1....
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
106.5.10 Assembly Area
For the purposes of these requirements, assembly areas include, but are not limited to, classrooms, lecture halls, courtrooms, public meeting rooms, public hearing rooms, legislative chambers...
-
106.5.63 Space
A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
1009.2.7 Operation
This will permit a person to call the pool lift when the pool lift is in the opposite position....
-
407.4.7.1.4 Visible Indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
407.4.8.1.3 Floor Arrival
EXCEPTION: Destination-oriented elevators shall not be required to comply with 407.4.8.1.3 provided that the visible indicators extinguish when the call has been answered....
-
106.5.73 TTY
TTYs are also called text telephones....
-
221.2.1.3 Other Boxes
For example, a concert hall has 20 boxes, each of which contains 10 seats, totaling 200 seats....