Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20....
Search Results "Counter Slope"
Commonly Searched Documents
-
406.2 Counter Slope
-
227.3 Counters
Where provided, at least one of each type of sales counter and service counter shall comply with 904.4....
-
904.4 Sales and Service Counters
Sales counters and service counters shall comply with 904.4.1 or 904.4.2. The accessible portion of the counter top shall extend the same depth as the sales or service counter top....
-
403.3 Slope
The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48....
-
810.5.1 Slope
Rail platforms shall not exceed a slope of 1:48 in all directions....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
405.3 Cross Slope
Cross slope of ramp runs shall not be steeper than 1:48. Advisory 405.3 Cross Slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
-
1009.3.1 Sloped Entries
Sloped entries shall comply with Chapter 4 except as modified in 1009.3.1 through 1009.3.3....
-
904 Check-Out Aisles and Sales and Service Counters
[See subsections ...]
-
904.2 Approach
All portions of counters required to comply with 904 shall be located adjacent to a walking surface complying with 403. Advisory 904.2 Approach....
-
231.4.1 Cubicles and Counters
Where counters are provided, at least one shall comply with 904.4.2 on both the visitor and detainee sides....
-
106.5.56 Running Slope
The slope that is parallel to the direction of travel (see cross slope)....
-
106.5.22 Cross Slope
The slope that is perpendicular to the direction of travel (see running slope)....
-
227.1 General
Where provided, check-out aisles, sales counters, service counters, food service lines, queues, and waiting lines shall comply with 227 and 904....
-
904.1 General
Check-out aisles and sales and service counters shall comply with the applicable requirements of 904....
-
227 Sales and Service
[See subsections ...]
-
1009.3 Sloped Entries
Sloped entries shall comply with 1009.3. Advisory 1009.3 Sloped Entries. Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
904.4.1 Parallel Approach
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
1002.4.2 Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position....
-
232.5.1 Cubicles and Counters
Where counters are provided, at least one shall comply with 904.4.2 on both the visitor and detainee or inmate sides....
-
810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
904.4.2 Forward Approach
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....
-
227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with 904.3 or 904.4 shall comply with 403....