Section 216.4 covers scoping requirements in the current ADA Standards for signs for means of egress.
Search Results "Evacuation Signage"
-
Means of Egress: ADA Standard Section 216.4
-
Directional and Informational Signs: ADA Standard Section 216.3
Section 216.2 covers scoping requirements in the current ADA Standards for directional and informational signs.
-
Visual Characters: ADA Standard Section 703.5
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
Directional Signs: ADA Standard Section 216.4.3
Section 216.4.3 covers scoping requirements in the current ADA Standards for directional signs.
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
Signs: ADA Standard Section 703
[See subsections ...]
-
Signs: ADA Standard Section 216
Section 216 covers scoping requirements in the current ADA Standards for signs.
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
Installation Height and Location: ADA Standard Section 703.4
Signs with tactile characters shall comply with 703.4.
-
Stroke Thickness: ADA Standard Section 703.5.7
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
Character Proportions: ADA Standard Section 703.5.4
Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
-
Character Spacing: ADA Standard Section 703.5.8
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
General: ADA Standard Section 703.1
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
Style: ADA Standard Section 703.5.3
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
General: ADA Standard Section 216.1
Section 216.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for signs.
-
Directional Signs: ADA Standard Section 216.9.2
Section 216.9.2 covers scoping requirements in the current ADA Standards for TTY directional signs.
-
Character Height: ADA Standard Section 703.5.5
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...
-
TTYs: ADA Standard Section 216.9
Section 216.9 covers scoping requirements in the current ADA Standards for signs for TTYs.
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
Line Spacing: ADA Standard Section 703.5.9
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
Identification Signs: ADA Standard Section 216.9.1
Section 216.9.1 covers scoping requirements in the current ADA Standards for TTY identification signs.